Water Environment Federation (WEF) Discussion Forums
Home      Members   Calendar   Who's On
Welcome Guest ( Login | Register )
      

Home » WEF Discussion Forums » Industrial Wastes Treatment » VFA/TA Ratio


VFA/TA RatioExpand / Collapse
Author
Message
Posted 3/21/2008 8:35:15 AM
Forum Newbie

Forum NewbieForum NewbieForum NewbieForum NewbieForum NewbieForum NewbieForum NewbieForum Newbie

Group: Forum Members
Last Login: 3/21/2008 8:27:30 AM
Posts: 7, Visits: 17
We have a anaerobic contact basin used for treating industrial wastewater. We currently have VFAs of 23 and a total alkalinity of 1500 (without NaOH being added).  Should I be concerned that the total alkalinity is 1500 (which some think is too low) or should I focus more on the VFA/TA ratio, which is .01 right now?  I believe that adding NaOH is not necessary as long as my ratio stays below .1.  I am not worried about a sudden increase in influent VFAs due to a large EQ tank ahead of the anaerobic contact basin.

THANKS!!

Post #8706
« Prev Topic | Next Topic »


Reading This TopicExpand / Collapse
Active Users: 1 (1 guest, 0 members, 0 anonymous members)
No members currently viewing this topic.

PermissionsExpand / Collapse

All times are GMT -5:00, Time now is 12:20am