All,

During our dechlorination agent conversion from SO2 to Sodium Bisulfite,WET bioassay monitoring was conducted with a >50% mortality to the Mysid Shrimp. The lab feels it was due to a overdosing of the bisulfide because only the shrimp was effected which I agree. Anyway, does anyone have experience with the bisulfite dosing? IE enough for chlorine removal but not overdosing.

Thanks,

Phil

Post #8217
Posted 2/1/2008 11:57:40 AM
Forum Member

Forum MemberForum MemberForum MemberForum MemberForum MemberForum MemberForum MemberForum Member

Group: Forum Members
Last Login: 4/17/2008 4:10:40 PM
Posts: 36, Visits: 149
Phil,

Using bisulfide for dechlorination is usually  1 part to 1 part. Excessive use of bisulfide will deplete oxygen and kill the test organisms.

Bob Whitworth

Post #8218
Posted 2/1/2008 12:24:11 PM
Forum Newbie

Forum NewbieForum NewbieForum NewbieForum NewbieForum NewbieForum NewbieForum NewbieForum Newbie

Group: Forum Members
Last Login: 2/7/2008 11:21:48 AM
Posts: 2, Visits: 11
Thanks! I thought DO was monitored & controlled at a level of >4.0 mg/l during the 96hr test period.
Post #8220
Posted 2/1/2008 1:43:00 PM
Forum Member

Forum MemberForum MemberForum MemberForum MemberForum MemberForum MemberForum MemberForum Member

Group: Forum Members
Last Login: 4/17/2008 4:10:40 PM
Posts: 36, Visits: 149
Phil,

You are most likely correct about maintaining the D.O. during the toxicity test procedure; it just came to mind about the D.O. depression.

Bob Whitworth

Post #8223
Posted 2/5/2008 12:42:09 PM


Supreme Being

Supreme BeingSupreme BeingSupreme BeingSupreme BeingSupreme BeingSupreme BeingSupreme BeingSupreme Being

Group: Forum Members
Last Login: Today @ 11:09:55 AM
Posts: 259, Visits: 689
We use a feedback loop using an on line analyzer like http://analyticaltechnology.com/cms/Default.aspx?tabid=89  It is relatively cheap and uses diluted sulfuric acid as its only reagent.  Be sure to install a system to bleach the sample lines automatically as bisulfite residual will grow slime that consumes both bisulfite and reacts with chlorine.

Bisulfite does have a BOD, but chemical DO consumption requires a catalyst like cobalt.  Old Std. Mthds. had an aerator test that depressed the DO by adding bisulfite and a cobalt catalyst.  Measuring DO drop due to bisulfite on the lab bench showed a DO increase due to the DO probe stirrer.  Adding a catalyst dropped the DO immediately.

Post #8263
« Prev Topic | Next Topic »

Reading This TopicExpand / Collapse
Active Users: 1 (1 guest, 0 members, 0 anonymous members)
No members currently viewing this topic.

PermissionsExpand / Collapse

All times are GMT -5:00, Time now is 2:35pm

Powered By InstantForum.NET v4.0.0 © 2008
Execution: 0.125. 9 queries. Compression Enabled.