We have been batteling some issues with our Stranco 960 for some time. Dechlorination has been iffy at best and charting the patterns of either the MCO and/or MV value are all over the place typically. Like many we run a 3 channel system and use #1 for Chlor, #2 for read only and #3 for Dechlor contol, reads on #2 are typically very close to the ORP value of #1 which is Chlorine. Here is a question I dont understand: Today we saw Ch #1 @ 400 mv which is fine, Channel #2 @ 390 which is fine also, Channel #3 set point is 150, Mv value goes down to 60, shuts off the pump, we take a residual and have near 5 MGL which is our CL2 dose moreless and should be 0 in light of the MV value showing 60. We swap the #2 channel and #3 channel probe tips and the dechlor channel comes right around to an actual 360 MV and starts to control the Dechlor pump ramping it up like it should be and the other tip now reads 60 MV in water that was just read at 390 MV and stays there for hours until it finally creeps up the anticipated 390. Inital thoughts were the probe is bad, mind you this is the 3rd time its been replaced in a month due to similar problems that keep comming back. I realize there is some "burn time" required but this is way out of range.
Any thoughts on this?
Post #5766
« Prev Topic
|
Next Topic »
Reading This Topic
Active Users: 1 (1 guest, 0 members, 0 anonymous members)
No members currently viewing this topic.
Permissions
You
cannot
post new topics.
You
cannot
post topic replies.
You
cannot
post new polls.
You
cannot
post replies to polls.
You
cannot
edit your own topics.
You
cannot
delete your own topics.
You
cannot
edit other topics.
You
cannot
delete other topics.
You
cannot
edit your own posts.
You
cannot
edit other posts.
You
cannot
delete your own posts.
You
cannot
delete other posts.
You
cannot
post events.
You
cannot
edit your own events.
You
cannot
edit other events.
You
cannot
delete your own events.
You
cannot
delete other events.
You
may
send private messages.
You
cannot
send email's.
You
may
read topics.
You
cannot
rate topics.
You
cannot
vote within polls.
You
cannot
upload attachments.
You
may
download attachments.
You
cannot
post HTML code.
You
cannot
edit HTML code.
You
cannot
post IFCode.
You
cannot
post JavaScript.
You
cannot
post EmotIcons.
You
cannot
post or upload images.
Forum Jump...
----------------
Forum Home
Search
Members List
Calendar
Who's Online
----------------
Welcome to WEF's Discussion Forums
|-- Forum Overview
|-- Terms of Use Agreement
WEF Discussion Forums
|-- Biological Nutrient Removal
|-- Biosolids & Residuals
|-- Collection Systems
|-- Industrial Wastes Treatment
|-- Laboratory Management & Technical Issues
|-- Leveraging “Liquid Assets” Local Activities
|-- Operation & Maintenance
|-- Utility Management
Archives
|-- Archived Forum Topics
|---- Academic and Student Issues
|---- Foros de Discusión Técnica
|---- Technical Discussion Group in Spanish
|---- Air Quality
|---- Disinfection
|---- Safety & Health
|---- Small Systems
|---- Microconstituents (may also be known as CPCs...
All times are GMT -5:00, Time now is 5:26pm
Powered By InstantForum.NET v4.0.0 © 2008
Execution: 0.078.
10 queries.
Compression Enabled.