Posted 3/18/2006 9:00:27 PM
Forum Newbie

Forum NewbieForum NewbieForum NewbieForum NewbieForum NewbieForum NewbieForum NewbieForum Newbie

Group: Forum Members
Last Login: 3/18/2006 8:55:52 PM
Posts: 1, Visits: 1
I am a new operator of a sequencing batch reactor plant in New Jersey.

I am having a problem with high ammonia in my effluent during cold weather.

I am also having a problem with the units shutting down for no reason.

If anyone can help me I would be very thankful.

Post #1382
Posted 3/22/2006 2:57:02 PM
Supreme Being

Supreme BeingSupreme BeingSupreme BeingSupreme BeingSupreme BeingSupreme BeingSupreme BeingSupreme Being

Group: Forum Members
Last Login: 6/18/2008 10:17:32 AM
Posts: 98, Visits: 161
Are you having any other problems?  Ammonia levels will be higher in the winter do the temp. change.  You are likely not nitrifying.  Try increasing your solids retention time.  Lesson the wasting.  Increase your aeration period.  What are your current MLSS?
Post #1414
Posted 6/3/2006 7:49:16 PM
Forum Newbie

Forum NewbieForum NewbieForum NewbieForum NewbieForum NewbieForum NewbieForum NewbieForum Newbie

Group: Forum Members
Last Login: 9/8/2006 8:10:42 PM
Posts: 6, Visits: 8
You may want to check your influent alkalinity.  It takes about 7.1 mg/l alkalinity to remove 1 mg/l NH3.  You may need to add lime or soda to increase alkalinity.

It's true that alkalinity removal in winter is not as efficient as in summer.  That's why some permits have lower limits during the warmer months.

Not sure why system would be shutting down without more info.  What manufacturer...Jettech, Aqua-aerobic, etc??

Post #1899
Posted 9/24/2006 4:20:18 PM
Junior Member

Junior MemberJunior MemberJunior MemberJunior MemberJunior MemberJunior MemberJunior MemberJunior Member

Group: Forum Members
Last Login: 4/23/2008 4:07:25 PM
Posts: 14, Visits: 44
For eight years, my company has run a 20,000 gpd avg flow / 55,000 gpd design flow SBR in Connecticut. We are able to maintain nitrification almost through the winter even though the wastewater temperature in the SBR drops to less than 10 degrees Celsius. It seem that just as the weather starts to improve we lose nitrification for a month or two. Our year-around-total Nitrogen level is good: well below 10 mg/L but it does jump to 20 from time to time. Luckily, DEP is okay with it.

Because our flow drops during the winter (thus the low temperatures), we add sugar to increase the loading on the plant. It really helps. We significantly reduce aeration cycle times, but not too low (don't want to talk about that experience!), and we maintain a wasting schedule even when the MLSS is slipping.  

I'd enjoy talking about what we are doing and what you are doing to maintain nitrogen removal. Click on the Water Planet name to the left and send me an email.

Post #2859
Posted 8/4/2007 6:03:47 AM
Junior Member

Junior MemberJunior MemberJunior MemberJunior MemberJunior MemberJunior MemberJunior MemberJunior Member

Group: Forum Members
Last Login: 2/1/2008 6:26:27 AM
Posts: 23, Visits: 77
As well as sludge age increased, you should look at the DO setpoint. A setpoint of 2.0 mg/L, instead of 1.0 in winter will improve nitrification.

Regards Grant H 

Post #6211
Posted 10/20/2007 6:01:03 PM
Forum Member

Forum MemberForum MemberForum MemberForum MemberForum MemberForum MemberForum MemberForum Member

Group: Forum Members
Last Login: 11/1/2007 1:40:20 PM
Posts: 26, Visits: 34
We have twin 50K GPD SBRs in a higher elevation area and have maintained nitrfication through the winter even though reactor temp has been in the range of 2.8 to 4 degC. Ammonia is 55-60 ish. We run MLSS about 5,000. We also fabricated several "baskets" with fine bubble diffuser in bottom with the plastic pasta wheels in the baskets to increase our bug mass while not increasing MLSS any further.

and the bug knows best
Post #7134
« Prev Topic | Next Topic »

Reading This TopicExpand / Collapse
Active Users: 1 (1 guest, 0 members, 0 anonymous members)
No members currently viewing this topic.

PermissionsExpand / Collapse

All times are GMT -5:00, Time now is 12:08pm

Powered By InstantForum.NET v4.0.0 © 2008
Execution: 0.172. 10 queries. Compression Enabled.